Materials and Methods
Ethics statement
The study was approved by the Ethical Committee of Haydarpasa Numune Research and Training Hospital (No. HNEAH-KAK-KK-2020-6). The study protocol adhered to the tenets of the Declaration of Helsinki. A written consent was obtained from all patients who took part in this study.
Study selection
In this retrospective, case-control study, we reviewed the medical records of patients who underwent uneventful phacoemulsification with posterior chamber IOL implantation at a single center, between January 2015 and April 2020. The exclusion criteria were as follows: preexisting comorbid eye conditions that could affect the refractive outcomes (a history of trauma, corneal disease, retinal disease, and uveitis), previous ocular surgeries, intraoperative complications (capsule tear, vitreous loss, retained lens fragments, zonular dialysis, and choroidal haemorrhage), postoperative complications (prolonged corneal oedema, macular oedema, retinal detachment, and uncontrolled IOP requiring additional medication or glaucoma surgery with-in 6 months postoperatively), combined procedures such as phacoemulsification-trabeculectomy or phacoemulsification-pars plana vitrectomy and lack of visual acuity, IOP, and refractive data at postoperative 6-month visits. The eyes with axial length ≤22.0 mm and ≥26.0 mm and with preoperative cylindrical value ≥3.0 diopters (D) were not included in the study. The control group included only those without pseudoexfoliation in both eyes.
The eyes that undergone uneventful cataract surgery with IOL implantation were classified into two groups. The study group including the eyes with pseudoexfoliation was categorized into two subgroups: PXS (eyes with pseudoexfoliation that did not have glaucomatous optic neuropathy and corresponding visual field defects) and PXG (eyes with pseudoexfoliation that had glaucomatous optic neuropathy and corresponding visual field defects). The normal eyes without pseudoexfoliation were included in the control group.
Surgical technique
All surgical procedures were performed under subtenon anesthesia. In all cases, a 2.8-mm clear corneal incision in the upper corneal limbus, 5 to 6 mm continuous curvilinear capsulorrhexis, hydrodissection, and phacoemulsification with the Infiniti Vision System (Alcon Laboratories, Fort Worth, TX, USA) were performed to remove the cataract. A nonsutured capsular tension ring (CTR) was implanted in eyes with zonular weakness. A foldable one-piece acrylic hydrophobic IOL (Eyecryl Plus ASHFY600; Biotech Vision Care, Ahmedabad, India) with manufacturer-recommended A-constants of 118.5 was implanted in the capsular bag. All patients used prednisolone acetate and moxifloxacin drops during the postoperative first month.
The preoperative data included sex, age at phacoemulsification, IOP, corrected distance visual acuity (CDVA) as the logarithm of the minimum angle of resolution (log-MAR), spherical equivalent (SE; spherical power +½ cylinder power), axial length (AL), IOL power (D), and predicted refraction. The measurement of refraction status was performed using an automatic refractor (Topcon KR-800A Auto Refractor Keratometer; Topcon Medical, Tokyo, Japan). The IOL power was calculated using partial coherence interferometry (IOL Master 500; Carl Zeiss Meditec, Jena, Germany). The SRK/T formula was used to calculate the IOL power.
Outcome measures
The primary outcome measure was the refractive error, defined as the difference in the predicted SE and postoperative SE at the 6-month visit. A refractive error >± 1.0 D was identified as a large-magnitude refractive error. The predictive refractive accuracy was analyzed, and the frequency of the refractive error was compared between eyes with and without pseudoexfoliation. The mean absolute error is defined as the absolute difference between the predicted SE and the actual postoperative SE. We also examined the difference in refractive outcomes between each subgroup and normal eyes. The mean IOP (average of two IOP measurements using Goldmann applanation tonometry), IOP change (difference between the preoperative and postoperative IOPs), and CDVA were recorded at 6-month visit. In the first postoperative 24 hours, an IOP >25 mmHg was defined as an IOP spike [
9,
10]. If an IOP spike occurred, the treatment was 250 mg of oral acetozolamid and injection of a 20% mannitol solution (1 g/kg). There was no requirement of additional medical treatment or surgery after acute episode in the eyes with an IOP spike. The need for a CTR during cataract surgery was also recorded.
A statistical analysis was performed using SPSS ver. 16.0 (SPSS Inc., Chicago, IL, USA). Normality for continued variables in a group was determined using the Kolmogorov-Smirnov test. Descriptive analyses were represented as mean and standard deviation for a normal distribution or median and range for an abnormal distribution with a value of p < 0.05. Groups were compared using the chi-square test or Fisher exact test for categorical variables and independent t-test or Mann-Whitney U-test for continuous variables. Independent predictors of the refractive error were determined by using binary logistic regression analysis. Patient age, sex, AL, preoperative CDVA, preoperative IOP, IOP change after phacoemulsification, PXS, PXG, CTR implantation during surgery, and presence of an IOP spike at postoperative first 24 hours were investigated as potential risk factors. First, each variable was analyzed in a univariate model. Next, all variables with a significance level of less than 0.20 were included in the multivariate model. A value of p < 0.05 was considered statistically significant.
Results
A total of 592 patients (720 eyes) who underwent uneventful phacoemulsification cataract surgery met the inclusion criteria. We included 170 patients (210 eyes) with pseudoexfoliation as the study group, and 422 patients (510 eyes) without pseudoexfoliation as the control group. In the study group, 70 patients (82 eyes) had a diagnosis of PXS, 100 patients (128 eyes) had a diagnosis of PXG. The patients’ data are summarized in
Table 1.
A summary of the descriptive statistics of the study and control eyes before (preoperative) and after (postoperative) cataract surgery with IOL implantation is reported in
Table 2. There was statistically significant difference in terms of preoperative IOP, IOP change after phacoemulsification, and postoperative CDVA between two groups (
p < 0.001). The postoperative CDVA (0.13 ± 0.33) was significantly worse in the eyes with PXG compared those with PXS (0.05 ± 0.69,
p = 0.01). There was no statistically significant difference for preoperative CDVA (
p = 0.10), preoperative IOP (
p = 0.08), postoperative IOP (
p = 0.05), and IOP change (
p = 0.70) in the subgroup analyses.
Tables 3 and
4 shows the refractive outcomes in the study and control groups. There was a significantly higher frequency of large-magnitude refractive and hyperopic errors in the study group, when compared with the control group (
p = 0.001 and
p = 0.003, respectively). A large-magnitude refractive error and a hyperopic refractive error were also significantly more common in the eyes with PXG (
p < 0.001) when compared to the control eyes. When we compared the refractive outcomes of PXG and PXS eyes with one another, only a hyperopic error was more frequent in PXG eyes (
p = 0.03). There was no statistically significant difference in the mean refractive error and mean absolute error between PXG and PXS subgroups (
p = 0.78 and
p = 0.56, respectively).
Univariate logistic regression analysis of risk factors for refractive error >±1.0 D in both study and control eyes was shown in
Table 5. Preoperative CDVA, IOP spike, and PXG were related with refractive error >±1.0 D. These three factors were added in the multivariate model. PXS was also added in the multivariate model for subgroup analysis. Multivariate logistic regression analysis of risk factors for refractive error >±1.0 D is shown in
Table 6. PXG and low visual acuity before cataract surgery were found to be risk factor for large-magnitude refractive error (
p = 0.001 and
p = 0.02, respectively).
In the study group, CTR was implanted in 12 eyes with PXG (9.4%) and seven eyes with PXS (8.5%). In the control group, CTR was implanted in only two eyes (0.4%). There was no statistically significant relationship between large-magnitude refractive error and CTR implantation in the PXG and PXS subgroups and in the control group (p = 0.51, p = 0.61, and p = 0.82, respectively).
Table 7 shows a comparison of risk factors between the eyes with and without large-magnitude refractive error in PXG eyes. At postoperative 24 hours, an IOP spike was seen in 37 normal eyes (7.3%) compared to 25 eyes (19.5%) with PXG (
p < 0.001) and 10 eyes (12.2%) with PXS (
p = 0.12). In the PXG subgroup, the eyes with refractive error >±1.0 D and hyperopic error >1.0 D after cataract surgery, had a significantly higher frequency of IOP spikes than those with no refractive error (
p = 0.01 and
p = 0.03, respectively). Using logistic regression analysis, the odds ratio of an IOP spike was 3.37 (95% confidence interval, 1.29-8.75), which was statistically significant for a large-magnitude refractive error (
p = 0.01) (
Table 8).
Discussion
Despite advances in technology involving phacoemulsification and IOL design, refractive outcomes of cataract surgery are not always perfect. Parameters, determining the IOL power to be used, include the lens constant provided by the manufacturer, keratometry measurements, ACD, and the AL of the eye [
11]. The SRK/T is a third generation theoretical formula that uses a modified ACD prediction algorithm [
12]. This formula calculates estimation of IOL position by considering the AL and corneal height.
This is the first study with a large series of refractive outcomes of eyes with pseudoexfoliation (210 eyes) and is the first comparison of the refractive errors after cataract surgery in patients with PXS and PXG. Our results showed that there was a significant difference in large-magnitude refractive error (>±1.0 D) and hyperopic error (>1.0 D) between eyes with and without pseudoexfoliation. Although there was no significant difference for each refractive error between PXS and normal eyes, in PXG eyes, large-magnitude refractive and hyperopic errors were significantly more frequent than in normal eyes. In addition, the incidence of a hyperopic error was significantly higher in PXG eyes than in PXS eyes.
There have been a few studies describing the refractive outcomes after cataract surgery in eyes with pseudoexfoliation. Ishikawa et al. [
8] observed 62 eyes with pseudoexfoliation. They reported that in eyes with pseudoexfoliation, the SE refraction errors were distributed more widely than in normal eyes in both myopic and hyperopic directions on the postoperative first day. There was no significant intergroup difference in refractive error at postoperative month 1. However, the patients were not clearly defined as PXS or PXG. In a study by Gur Gungor et al. [
6], PXS (n = 22) and normal eyes (n = 30) were compared for refractive outcomes and ACD changes after uneventful phacoemulsification. At postoperative month 3, the change in ACD was significantly larger in PXS eyes than in normal eyes. The mean absolute refractive error calculated using different IOL formulas (SRK/T, Haigis, Hoffer, and Holladay 1) was not statistically significant between the two groups. In the present study, 82 eyes with PXS had no significant frequency of refractive error when we compared with normal eyes, consistent with other recent studies.
Several studies have reported significant deepening of the anterior chamber with a reduced IOP after phacoemulsification in normal eyes [
13,
14]. They found that the decrease in IOP did not correlate with the degree of increase in the ACD. In our study, the decrease in IOP was significantly greater in eyes with pseudoexfoliation than in eyes without pseudoexfoliation, and this difference in IOP change did not correlate with the refractive outcomes.
Ucakhan et al. [
15] and Kim et al. [
16] reported that the shallower the preoperative anterior chamber, the deeper it became postoperatively. Ning et al. [
17] indicated that a hyperopic or myopic shift often occurs with different degrees of change in the ACD. Muzyka-Wozniak and Ogar [
18] found that the relative change in the ACD was larger in short eyes than in normal eyes or long eyes, which means that the AL influenced changes on the postoperative ACD.
Only one study has evaluated anterior segment parameters in PXG and PXS eyes. They found that there was a significant difference in means of ACD values, compared to normal eyes in the PXG group but not in the PXS group [
19]. In the Yang et al. [
20]’s study, hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened. There were significantly more frequent hyperopic refractive errors in PXG eyes than in PXS and normal eyes in our study. Hyperopic error could be explained by a preoperative shallower ACD and postoperative higher increase in ACD in PXG eyes, when compared with PXS and normal eyes.
Several risk factors for deviating from the predicted postoperative refraction have been reported. These include older age, sex, glaucoma, poor preoperative visual acuity, previous eye surgery, surgical complications, AL measurement, and estimation of IOL position [
21-
23]. They suggested that a measurement error in biometry and keratometry in patients with low preoperative visual acuity could negatively affect refractive outcomes after cataract surgery. The subtypes of glaucoma and the myopic or hyperopic refractive error were not specified in this study. In the present study, poor visual acuity before cataract surgery was related with refractive error. Manoharan et al. [
24] reported that primary open-angle glaucoma, PXG, and chronic angle-closure glaucoma eyes had higher odds for large-magnitude refractive errors than eyes without glaucoma, but only PXG and chronic angle-closure glaucoma eyes were statistically significant. Until our study, it was the first study that analyzed PXG (23 eyes) as a risk factor for refractive error after cataract surgery. Our study included a larger case series for PXG group (n = 128) that showed higher odds of a large-magnitude refractive error and hyperopic error when compared with PXS and normal eyes.
In our study, there was no statistically significant relationship between large-magnitude refractive error and CTR implantation in the PXG and PXS subgroups and in the control group. This result was similar to previous publications [
25,
26].
Yeh et al. [
27] showed that an IOP spike of >50% above the baseline IOP may contribute to a myopic condition in the low preoperative IOP (<9 mmHg) group in the trabeculectomized eyes. They suggested that a period of higher IOP after phacoemulsification stretches the eye, resulting in a longer AL and induction of a myopic shift. Lee et al. [
28] reported a significant relationship between unpredictable refractive outcomes and acute angle-closure glaucoma duration in primary angle-closure glaucoma patients. They suggested that the longer the duration of IOP elevation, the greater the likelihood that zonular instability will occur, so in patients with a longer acute angle-closure glaucoma duration could explain why unpredictable refractive outcomes frequently develop in these patients after cataract surgery. In the present study, the IOP spike was more common in the PXG subgroup (20%). The only significant predictive factor, found in our study related to large-magnitude refractive error and hyperopic error, was the presence of an IOP spike in PXG eyes. A hyperopic shift in ocular power occurs when an IOL is implanted in a more posterior plane than preoperatively planned [
29]. An IOP spike may cause the postoperative ACD to be deeper than predicted, with preexisting zonular instability. It could explain why a hyperopic refractive error was more frequently seen in PXG eyes with an IOP spike.
As a limitation we could not observe the keratometry values, ACD, and AL changes after phacoemulsification because of the retrospective nature of the study. Also, IOL power was calculated with SRK/T, so we could not draw any conclusions about the influence of different IOL calculations on the refractive outcome. There is a need for additional prospective and randomized studies to evaluate the relationship between refractive outcomes and changes in anterior chamber parameters after cataract surgery in PXG eyes.
In conclusion, in the present study, we observed that the eyes with PXG but not PXS were at high risk for refractive error, particularly hyperopic shift. The presence of an IOP spike was related to large-magnitude refractive error and hyperopic error in PXG eyes. In PXG, the cause of refractive surprises after uneventful cataract surgery, may be related to unpredictable ACD changes in the presence of zonular weakness.