Predictability for proper capsular tension ring size and intraocular lens size.
E Y Dong, C K Joo
Korean J Ophthalmol. 2001;15(1):22-26.   Published online 2001 Jun 30     DOI: https://doi.org/10.3341/kjo.2001.15.1.22
Citations to this article as recorded by Crossref logo
Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies
Xuanqiao Lin, Dongmei Ma, Jin Yang
Frontiers in Medicine.2024;[Epub]     CrossRef
Propensity-matched comparison of postoperative stability and visual outcomes of toric intraocular lens with or without a capsular tension ring and updated meta-analysis
Dongmei Ma, Xiaoyan Han, Zhixiang Hua, Jiying Shen, Limei Zhang, Tian Qiu, Jianfeng Luo, Lei Cai, Jin Yang
Graefe's Archive for Clinical and Experimental Ophthalmology.2023; 261(4): 989.     CrossRef
Artificial iris implantation in congenital aniridia: A systematic review
Davide Romano, Dominique Bremond-Gignac, Miriam Barbany, Amna Rahman, Laura Mauring, Francesco Semeraro, Claus Cursiefen, Neil Lagali, Vito Romano
Survey of Ophthalmology.2023; 68(4): 794.     CrossRef
Rotational stability of plate-haptic toric intraocular lenses in Asian eyes: risk period for intraocular lens rotation and its influencing factors
Dongmei Ma, Jiying Shen, Tian Qiu, Limei Zhang, Zhixiang Hua, Lei Cai, Jin Yang
Journal of Cataract and Refractive Surgery.2023; 49(3): 253.     CrossRef
Biometry of the human cornea and globe: An evaluation by age, gender and population
Robert C. Augusteyn, Ashik Mohamed
Experimental Eye Research.2022; 216: 108932.     CrossRef
Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age
Ashik Mohamed, Sushma Nandyala, Arthur Ho, Fabrice Manns, Jean-Marie A. Parel, Robert C. Augusteyn
Experimental Eye Research.2021; 209: 108653.     CrossRef
Risk Factor for Transient Hyperopic Refractive Outcome at Acute Postoperative Period After Panoptix Intraocular Lens Implantation
Sohee Jeon, Ayoung Choi
Clinical Ophthalmology.2021; Volume 15: 2499.     CrossRef
Long-Term Clinically Significant Posterior Capsular Opacification Development Pattern in Eyes Implanted with an Aspheric Monofocal Intraocular Lens with a Square Optic Edge
Javier Placeres Dabán, Juan Carlos Elvira, César Azrak, Lucía Rial, David P. Piñero, José I. Belda, Alessandro Meduri
Journal of Ophthalmology.2021; 2021: 1.     CrossRef
Decentration of a toric intraocular lens implant in a patient with simple megalocornea
Irene C. Kuo
American Journal of Ophthalmology Case Reports.2020; 19: 100754.     CrossRef
Agreement between anterior segment parameters obtained by a new ultrasound biomicroscopy and a swept-source fourier-domain anterior segment optical coherence tomography.
Xiuyuan Li, Pingjun Chang, Zhangliang Li, Shuyi Qian, Zehui Zhu, Qianwei Wang, Zhao Yun-E
Expert Review of Medical Devices.2020; 17(12): 1333.     CrossRef
A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: correlation between ocular biometric parameters
Mohammad Ghoreishi, Mehdi Abdi-Shahshahani, Alireza Peyman, Mohsen Pourazizi
International Ophthalmology.2019; 39(3): 661.     CrossRef
The Use of Capsular Tension Rings to Reduce Refractive Shift in Patients With Implantation of Trifocal Intraocular Lenses
Kristin Nistad, Frida Göransson, Eivind Støle, Hossein Shams, Björn Gjerdrum
Journal of Refractive Surgery.2017; 33(12): 802.     CrossRef
Analysis of factors of variation in lens equatorial length and axial globe length measurements using ultrasonography in dogs with cataract
C. Barbé, N. Harran, F. Goulle
Revue Vétérinaire Clinique.2017; 52(2): 33.     CrossRef
Novel technique to measure horizontal corneal diameter using a Scheimpflug image on the Pentacam
Youngje Sung, Sokjoong Chung, Sang Min Nam
Contact Lens and Anterior Eye.2016; 39(3): 234.     CrossRef
All about capsular tension rings
Charles H. Weber, Robert J. Cionni
Current Opinion in Ophthalmology.2015; 26(1): 10.     CrossRef
A pilot study on the corneal curvatures and ocular dimensions of horses less than one year of age
W. M. TOWNSEND, N. WASSERMAN, S. JACOBI
Equine Veterinary Journal.2013; 45(2): 256.     CrossRef
Surgical correction of astigmatism during cataract surgery
Phillip J Buckhurst, James S Wolffsohn, Leon N Davies, Shehzad A Naroo
Clinical and Experimental Optometry.2010; 93(6): 409.     CrossRef
Rotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devices
Joon Young Hyon, Hwan Eok Yeo
American Journal of Ophthalmology.2010; 149(2): 253.     CrossRef
Evaluation of the relationship between corneal diameter and lens diameter
Christopher Khng, Robert H. Osher
Journal of Cataract and Refractive Surgery.2008; 34(3): 475.     CrossRef
The analysis of predicted capsular bag diameter using modified model of capsule measuring ring in Asians
Jin‐Hyoung Kim, Doh Lee, Young‐Dong Cha, Sae‐Hoon Oh, Ki‐Choong Mah, Moo‐Suk Lee
Clinical & Experimental Ophthalmology.2008; 36(3): 238.     CrossRef
Early rotational stability of the longer Staar toric intraocular lens
David F. Chang
Journal of Cataract and Refractive Surgery.2003; 29(5): 935.     CrossRef